In order to ensure the uninterrupted operation of the electromagnetic heating controller, it is necessary to protect and maintain it regularly:
1. Always add lubricant to the movable part of the electromagnetic brake.
2. Check the length of armature stroke regularly. During the operation of the brake, the stroke length of the armature will increase due to the wear of the cutting surface. When the armature stroke length does not reach the normal value, it is necessary to adjust to restore the small gap between the braking surface and the rotary table. If the armature stroke length increases above the normal value, the suction may be greatly reduced.
3. If the worn brake surface is replaced, the small gap between the brake surface and the rotary table shall be properly adjusted from scratch.
4. Always check the tightening degree of bolts, especially the bolts of electromagnet, the bolts of electromagnet and shell, the bolts of yoke, the bolts of electromagnet coil and wiring bolts.
5. The electromagnetic heating controller regularly checks the mechanical wear of the movable parts and removes the dust, flower hair and dirt on the surface of the electromagnet parts.
Article from:http://worfhack.cn
11-29
Detection method of common faults of medium frequency electric furnace
1. First, observe whether the indication values of the four small meters in the if cabinet are normal. The rectifier operated voltmeter is 30V, the rectifier pulse ammeter is 130 ~ 150mA, the inverter operated voltmeter is 12V, and the inverter pulse ammeter is 100 ~ 120mA. If the value is withi
11-29
How to maintain the medium frequency electric furnace?
1. Regularly remove the dust in the power cabinetIn particular, the outside of the thyristor core shall be wiped clean with alcohol. The frequency conversion equipment in operation generally has a machine room, but the actual working environment is not ideal. In the smelting and forging proc
11-29
How to maintain the electromagnetic heating controller?
In order to ensure the uninterrupted operation of the electromagnetic heating controller, it is necessary to protect and maintain it regularly:1. Always add lubricant to the movable part of the electromagnetic brake.2. Check the length of armature stroke regularly. During the operation o
11-29
Causes of abnormal starting of medium frequency electric furnace
What is the cause of abnormal start of medium frequency electric furnace?Lack of phase of rectifier: the fault is that the sound is abnormal during operation, the larger output voltage rises below the rated value, and the abnormal noise announced by the power cabinet is becoming larger and l